ADDITIONS, ALTERATIONS, NEW CONSTRUCTION (RESIDENTIAL)

Any required Zoning Permits or Drainage Permits must be obtained prior to the start of work

  • The submitted construction drawings shall be signed and sealed by an Architect or Engineer licensed in the Commonwealth of Pennsylvania. Construction drawings shall include, but not limited to, the following:
    • Foundation Plan indicating:
      • Dimensions of the structure and foundation.
      • Depth and width of the footings (concrete footings to be a minimum of 36 inches below finished grade, 8 inches thick, and 2,500 psi).
      • Size, thickness, and materials used for foundation walls.
      • Details on sub-grade material and preparation.
    • Floor Plan by level indicating:
      • Interior layout and dimensions with bearing and nonbearing partitions.
      • Beams and supports with materials, sizes, spacing, and spans.
      • Size, spacing, span, and bridging of floor joists.
      • Smoke and carbon monoxide detector locations.
      • Optional Framing Plan upon Township’s request.
    • Roof Plan indicating:
      • Size, spacing, and span of ceiling joists.
      • Size, spacing, span, and slope of rafters.
      • Size of the ridge.
      • Size and spacing of collar ties.
      • Type, thickness, and R-factor of insulation.
      • Details on sheathing, flashing, felt, and shingles.
      • Details on roof openings, including attic ventilation, valleys, access, and connections.
    • Wall Section indicating:
      • Wall plates, stud sizing and placing, type and placement of rack bracing.
      • Details of facade materials.
      • Clear span for cantilever frame sections and headers above openings.
      • Type, thickness, and R-factor of insulation or Res Check for energy compliance.
    • Cross Section indicating:
      • Foundation and framing members including pre-engineered structural members.
      • Certification stamped by an Engineer licensed in the Commonwealth of Pennsylvania for each type of pre-engineered structural members.
  • Submit two (2) copies of the electrical wiring diagram approved by one of the Approved Electrical Underwriters attached to this Application.
  • Submit two (2) copies of the plumbing system showing the size of all drains, vents, traps and materials.
  • For new residential dwellings, submit two (2) copies of the mechanical system showing the duct work, complete heat loss calculation, and specifications.
  • For additions or alterations to residential dwellings, submit two (2) copies of the mechanical system showing the duct work and complete heat loss calculation for a new heater.  If using an existing heater, the complete heat loss calculation must treat the existing space and addition as one unit.



Show All Answers

1. ADDITIONS, ALTERATIONS, NEW CONSTRUCTION (RESIDENTIAL)
2. DECK CONSTRUCTION (RESIDENTIAL)
3. DEMOLITION
4. FINISHED BASEMENT
5. GEOTHERMAL SYSTEM INSTALLATION
6. SOLAR PANEL INSTALLATION
7. STANDBY GENERATOR
8. SWIMMING POOL CONSTRUCTION